Installation ––––––––––––––––––––––––––––––––––––––––––––––––––––––
Installing Feet – Required
1. Remove feet from plastic bag packed inside refrigerator.
2. Tip refrigerator back and screw feet in all the way to stop (they will
extend 2 mm below base of EREF).
3. Adjust feet as needed to level EREF in both directions. To access legs,
remove the lower front panel. Turn legs clockwise to extend legs.
Installing Shelves – Required
1. Remove shelves and shelf brackets packed inside refrigerator.
2. Install shelf brackets in pilasters (insert top tab, squeeze and push in lower
tab).
3. Position shelves on shelf brackets in a position to achieve even
distance between shelves (approx. 145mm).
4. Use a pliers to remove the upper screw of the pilaster and install the bracket
securing the shelves.
Changing Temperature Controller Settings – Optional
Follett's temperature controller is pre-programmed with a 4 C set point and
°C display. The 4 C set point delivers a temperature range of 4 C – 6 C that
may not meet the needs of your specific application. Follett's controller set
point can be changed to deliver the required range. Refer to page 6 for
instructions on changing set point.