4.12.1 Backflow valve
The backflow valve is located inside the sump at the internal
drain hose inlet. It prevents waste water from entering the sump.
1. Backflow valve assembly
2. Flap
4.13

Tank with base and sump

4.13.1 Tank, base and sump assembly
The tank, base and sump are assembled as one unit and aren't
available as a service part. If plastic cable holders, part holders
and screw holes are damaged or stripped, the entire dishwasher
must be replaced.
702_58300000130262_ara_en_c
4.13.2 Rear leveling foot
The rear leveling foot can't be adjusted from the front – the rear
foot is the same as front feet and is adjusted the same way. The
base has provision for two rear feet in the rear corners, but the
center foot factory mounting should be used (below left).
Factory feet positions, like the center rear foot (1), have
provisions for set screws (below right). Outside rear positions
1
don't have set screw positions and shouldn't be used.
screws are in the installation parts bag.
2
X
X
1 – Center rear foot set screw location
!
!
Set
1