Problem
Cause
Unit never produces
RO water/only provides
Low Feed Water Pressure
bypass water
Low Feed Water Pressure
RO Membrane Fouled
Unit Runs Low
Storage Tank Air Charge
or Out of Water
is Low
Pre-Filter is Plugged by
Sediment (Particles)
Slow Leak In the
Distribution Line
RO Membrane Partially
Fouled, Unit cannot produce
enough water to keep up
with demand
Unit Never Shuts Off
(Continually Runs to
Drain)
Product water check valve,
within the RO Membrane
allowed storage tank to
flow backwards to drain

Troubleshooting Guide

Solution
Repair existing Booster
Pump
Add Water Booster Pump
Repair Existing Booster
Pump / System
(If Applicable)
Add Water Booster Pump
Replace RO Membrane
Drain Tank using Sample
Valve, with Sample Valve
Open, Pump Up Air Charge,
8 to 10 psi, Close Sample
Valve
Replace Pre-Filter
Repair Leak
Replace RO Membrane
Check Reject Water flow
to drain in the morning.
Unit should be off and
no flow to drain. If flow
to drain exists, turn off
the feed water valve and
check for flow to drain in
10 minutes. If flow to drain
remains steady, replace
RO Membrane.
10
Notes
Contact Dealer
Only if Booster Pump is not
installed.
Contact Dealer
Only if Beverage Booster
System is not installed
Feed Water Pressure,
Temperature, RO
Membrane Flow Rate
should be checked before
replacing Membrane
Unscrew Blue Cap to
Access Schrader Air Valve
A more frequent pre-filter
change-out schedule may
be needed or use
HF60-CL or HF90-CL for
high sediment load area
The unit produces water
slowly. A dripping leak
can prevent the tank from
filling
High levels of hardness
minerals may be present
in feed water, monitor
reject flow for plugging,
contact dealer to add a
water softener
Reject Water flow to drain
should stop when the feed
water valve is off.