• Where a booster pump is installed on a water system, you MUST maintain and inspect the
attached pressure switch regularly in accordance with the booster pump manufacturer's
instructions. Contact a plumbing professional if you are uncertain how to maintain your
booster pump system.
• Where a booster pump is installed on a water system, you MUST install an appropriate
pressure relief valve. Pressure relief valve must be maintained and inspected every 6
months. Contact a plumbing professional if you are uncertain how select/install/maintain a
pressure relief valve.
• Where a booster pump is installed on a water system, you MUST install an appropriate
pressure regulating valve and regulate water pressure to <80 psi. Contact a plumbing
professional if you are uncertain how select/install/maintain a pressure regulating valve.
• DO NOT install in direct sunlight or outdoors.
• DO NOT install near water pipes which will be in path of a drilling tool when selecting the
position to mount the bracket.
• Mount filter in such a position as to prevent it from being struck by other items used in the
area of installation.
• Ensure that the location and fasteners will support the weight of the system when installed
and full of water.
• Ensure all tubing and fittings are secure and free of leaks.
These systems are intended for use on feedwater meeting the following parameters.
Be sure to confirm that the feedwater falls within the limits shown below. If you're not sure if this has been done,
check with your distributor before installing the system.

Feedwater Parameters:

Feed TDS . . . . . . . . . Up to 2,000 ppm (mg/L)
Hardness* . . . . . . . . . . <10 grains (171 mg/L)
Iron (Fe) . . . . . . . . . . . . . . . . . . . . <0.1 mg/L
Hydrogen Sulfide . . . . . . . . . . none allowable
Feed pH . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Free chlorine . . . . . . . . . . . . . . . . . . . <2 mg/L
Manganese (Mn) . . . . . . . . . . . . . <0.05 mg/L
Turbidity . . . . . . . . . . . . . . . . . . . . . . .<5 NTU
For areas with high dirt/sediment in incoming water, HF60-CL or HF90-CL pre-filter is recommended.
* NOTE: For waters over 10 grain hard, a 3M water softener is recommended for pretreatment. Consult 3M technical services for correct sizing.
For areas with incoming pressure less than 60 psi an external Booster Pump is required.
FEEDWATER PARAMETERS
Pressure . . . . . . 60-125 psi (4.12 - 8.62 KPA)
Temperature . . . . . . . . . .40-100°F (4.4-38°C)
2