Elegen SOUS COOKER PROFESSIONAL Manuel de fonctionnement, d'utilisation et d'entretien - Page 13

Parcourez en ligne ou téléchargez le pdf Manuel de fonctionnement, d'utilisation et d'entretien pour {nom_de_la_catégorie} Elegen SOUS COOKER PROFESSIONAL. Elegen SOUS COOKER PROFESSIONAL 16 pages. Low temperature immersion cooking system

MANUAL CODE: XXXXX
ISSUE DATE: 15/01/2018 vers_00_05
with the probe at the heart or one or more steps with independently timed cooking. Simply using the relevant dial, the
programs will also be maintained in the event of a power cut.
It is possible to view the parameters of the cooking cycle, the maximum temperature, average temperature, the minimum
temperature and the total time of the cooking cycle from when it turns on until the Sous Cooker goes off, the preheating cycle is
excluded from the sampling, also the heating cycle is excluded from sampling, temperature values are considered only from
when the temperature reaches the set point.
At the end of the work cycle or during the work cycle it is possible to view the sampled parameters in the following way:
1) By pressing the OK key, the values will be scanned automatically or manually by pressing the OK key repeatedly.
tEnp HI = maximum absolute temperature peak
tEnp AU = average temperature of the cycle
tEnp LO = minimum absolute temperature peak
xx.xx tin tot _ total cycle timer (xx.xx = total cycle time)
After pushing Ok button if the parameters are not displayed, wait several minutes and try again, infact some control filters are
inserted to avoid incorrect sampling.
The visualization of the cycle parameters at the end of a phase thermal sequence firing (TPS) will give the mean and maximum
minimum values of the entire thermal sequence.
If the preheating function is used, it may happen that the maximum temperature peak is much higher than the set point
temperature. This depends on the speed with which the temperature decreases from the moment of insertion of the product in
the tank. Sampling is carried out after about 2 minutes from the end of the pre-registration..
SOUS COOKER has a table inside of factory preset parameters. This table can be reloaded at any time
and is particularly useful in the event of system malfunctions. In this case, you should simply reload the data to restore the
system.
To reload the default data, proceed as follows:
1) Switch off the SOUS COOKER on the main switch
Press the
2)
Setting key and keep it pressed
Switch on the
3)
SOUS COOKER on the main switch, keeping the Setting key pressed
Release the
4)
Setting key as soon as the writing DEFAULT appears
The factory data were reloaded, in this case, all the programmings implemented by the user were lost.
SOUS COOKER is equipped with a full hour counter or a cycles counter that keeps track of the actual working hours or the
number of actual cycles.
To display the hour counter and cycles counter
1) Switch off the SOUS COOKER on the main switch
2) Press the STOP/START/ESC key and keep it pressed
3) Switch on the SOUS COOKER on the main switch, keeping the T/t key pressed
4) Release the STOP/START/ESC key, when the CYCLE xxxxxx message appears indicating the number of cycles
5) To view the number of hours, press the OK key or wait a few seconds for the HOUR xxxxxx message
to be automatically displayed.
SOUS COOKER is equipped with some controls to determine alarm situations for which the cycle is interrupted, when an
alarm condition is created, the cycle is blocked and the type of alarm is indicated on the display which is generated, at the same
time, the ALARM led is switched on,
The alarms managed by SOUS COOKER are the following:
1) Water level alarm, immediate alarm message – no LEVEL –
2) Main probe alarm, it is the probe inside the SOUS COOKER measuring the temperature of the tank. -noPROBE1-
3) No heating, if the temperature does not increase in value, -HEATING-
4) High temperature, if the temperature exceeds the HIGH TEMPERATURE set point temperature by some degrees
5) High temperature, at the heart of the product if the temperature at the heart of the product exceeds the HIGH HEART
set point temperature by some degrees
To reset the alarm, press any key.
ELEGEN by Quaglia Luigi - Via Jmre Nagy 8-8/A 42019 - Scandiano Reggio Emilia Italy- VAT No. 02018620357
TEL.+390522859721 – FAX +390522767677 -
PROFESSIONAL SOUS COOKER
Rev. 00.00 WITH REFERENCE TO FIRMWARE VERSION :00_15 and more
7.9 DISPLAYING CYCLE PARAMETERS

8.0 DEFAULT PARAMETERS

8.1 HOUR AND CYCLE COUNTERS

9.0 ALARMS

VOIP Skype. eleg2002
- Web-www.elegen.it - email
Page 13 of 16