3M Litmann Quality 3100 Manuel d'instructions - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel d'instructions pour {nom_de_la_catégorie} 3M Litmann Quality 3100. 3M Litmann Quality 3100 16 pages. Mining cable splice kit
Également pour 3M Litmann Quality 3100 : Manuel de démarrage rapide (2 pages)
6.0
Prepare Cable
6.1
Position cable ends so that conductor color rotation matches.
6.2
Circle-cut cable jacket approximately 12" (305 mm) from each end. Be sure not
to damage cable conductors.
6.3
Measure approximately 14" (355 mm) from cable end and fully taper cable
jacket down to circle cut.
4"
(100 mm)
Scuff & Clean
Circle cut cable jacket
6.4
Remove approximately 12" (305 mm) of cable jacket.
6.5
Scuff and clean 4" (100 mm) of cable jacket beyond each split end.
6.6
Remove cable fillers.
Instructions for Round Cables
3M
Temflex
Vinyl Electrical Tape 1700P
™
™
Figure 16
Figure 17
Scotch
Heavy Duty Mining Tape 31
®
Scotch
Linerless Rubber Splicing Tape 130C
®
3M
Temflex
™
Scotch
Linerless Rubber Splicing Tape 130C
®
3M
Temflex
™
14"
(355 mm)
12"
(305 mm)
8
Vinyl Electrical Tape 1700P
™
Electrical Vinyl Tape 1700P
™
78-8127-6830-3-C