Prepare Cable

6.1
Position cable ends so that conductor color rotation matches.
6.2
Circle-cut cable jacket approximately 12" (305 mm) from each end. Be sure not
to damage cable conductors.
6.3
Measure approximately 14" (355 mm) from cable end and fully taper cable
jacket down to circle cut.
4"
(100 mm)
Scuff & Clean
Circle cut cable jacket
6.4
Remove approximately 12" (305 mm) of cable jacket.
6.5
Scuff and clean 4" (100 mm) of cable jacket beyond each split end.
6.6
Remove cable fillers.
Instructions for Round Cables
3M
Temflex
Vinyl Electrical Tape 1700P
Figure 16
Figure 17
Scotch
Heavy Duty Mining Tape 31
®
Scotch
Linerless Rubber Splicing Tape 130C
®
3M
Temflex
Scotch
Linerless Rubber Splicing Tape 130C
®
3M
Temflex
14"
(355 mm)
12"
(305 mm)
8
Vinyl Electrical Tape 1700P
Electrical Vinyl Tape 1700P
78-8127-6830-3-C