Connections to the Alarm are made through input and output connectors. Customer supplied cables are easily
soldered to the connectors prior to plugging the connectors into the Alarm. For connector pin assignments please
refer to the "CONNECTING THE ALARM" section of this manual.
Correcting the low pressure condition will return the status lights back to green, and de-activate the relays.
The Multi-Station Remote Alarm can detect if the connection to the Autoswitch is broken. If the cable is
disconnected or a line is severed, the alarm will sound. This feature is only available when using normally closed
pressure switches.
Another feature in the Multi-Station Remote Alarm is Self Test. Pressing the "Test" button on the front of the unit
will allow all status lights and outputs on the Remote Alarm to be cycled.
The Serial Port on the Multi-Station Remote Alarm also reports the alarm status. Each time there is a change to
the status of the Remote Alarm, it will send this information to the Serial Port. Refer to the Serial Port section for
details.

INTENDED USE OF PRODUCT

The Multi-Station Remote Alarm is used to monitor and report the status of inlet pressure on AutoSwitch Systems.
The Alarm can be configured to monitor up to four (4) AutoSwitch Systems. The Alarm contains one (1) common
and four (4) independent sets of relay contacts as outputs that can be used to control any device that can be activated
using a normally open or normally closed switch. One example of such a device would be the CONCOA telephone
dialer (PN 5295306).
Connections to the Alarm are made through input and output connectors. Customer supplied cables are easily
soldered to the connectors prior to plugging the connectors into the Alarm. For connector pin assignments please
refer to the "CONNECTING THE ALARM" section of this manual.

USER RESPONSIBILITY

Service to this product should only be performed by CONCOA or an authorized CONCOA agent. Requests for
service may be made through CONCOA CUSTOMER SERVICE at 1-800-225-0473. Written requests may be
made using CONCOA's FAX number at 1-757-422-3125 or CONCOA's E-MAIL at [email protected].
CONCOA accepts no responsibility for damage or injury if this product is modified in any way.
CONCOA assumes/accepts no liability or responsibility for damage to individuals or equipment that may occur
when using this product.
SAFETY
Basic safety precautions must be followed to reduce the risk of fire, electrical shock or injury.
a. Connect the Alarm to the correct line voltage. A label on the product identifies whether it is wired for 120
VAC or 220VAC.
b. While the Alarm is dust and moisture resistant, it should be installed in a location where it will not be
subjected to rain or high concentrations of dust. Never pour or spray liquids directly onto the product.
c. Install the Alarm where the ambient temperature range while operating is between 0
d. Do not install the product in hazardous locations.
e. If product appears damaged in any way, do not use and request service from CONCOA.
f.
Do not attempt to operate the Alarm with the cover off.