11. (Optional Step) Navigate to the Exciter "SYSTEM" submenu and select
UPDATE under ADPC to run corrections. The exciter will then proceed through
4 stages of correction, computing Linear and Non-Linear corrections, and
automatically saving the coefficients into non-volatile memory upon
completion. The correction process typically takes from 8-10 minutes to
complete while real-time performance metrics of SNR and Shoulder
performance are displayed on the LCD.
12. Check RF Performance metrics (SNR, LIMD, UIMD) on the front panel screen
of the exciter, as well as on the PA's touchscreen.
Your TX should now be up and running properly into your load or on-air
antenna. Continue to monitor system parameters as you allow the transmitter to
operate and stabilize at full output power for another 30 minutes.
13. Navigate to the CAL setting under the AD3 Advanced submenu and select CAL
then press OK to calibrate the FWD PWR meter on the Exciter front panel to
100%.
14. To turn the TX On/Off, please use the RF On/OFF control in the RF submenu
of the exciter LCD or the exciter web interface. You may also use the TX
ON/OFF button on the PA's Home page, as shown below.
ACT-PAVIII1-QSG-DOC-V1.1, 06/26/2018
ATSC VHF 100W Quick Start Guide