■Light ON/Dark ON setting
Set Light ON/Dark ON.
- Address writer (ARW-04): Parameter 06
Variable
Details
0
Transmission type dark (shielding) ON
1
Transmission type light (transmission) ON
2
Re ection type dark (w/o re ection) ON
3
Re ection type light (w/ re ection) ON
■Setting for operation mode change
Set if there is a diagnosis mode.
- Address writer (ARW-04): Parameter 07
Variable
Details
0
Disabled (Simple mode)
1
Enabled (Normal mode)
■ Light receiving level display setting
Set the display of the light receiving level.
- Address writer (ARW-04): Parameter 08
Variable
Details
0
AD value display (0 - 4095 Digit)
1
0 - 100% display
(7-segment display)
Fiber side
ON/OFF threshold display (Green)
For "Parameter 8 variable 0: AD value display" - Displays
the threshold set in the scope of 0 - 4095.
For "Parameter 8 variable 1: 0 - 100% display" -
Displays the setting threshold from 0 - 100%, with the
minimum AD value from teaching as 0 and the maximum
as 100%.
Light receiving level display (Red)
For "Parameter 8 variable 0: AD value display" - Displays
the amount of light received converted as an AD value
set in the scope of 0 - 4095.
For "Parameter 8 variable 1: 0 - 100% displays" -
Displays the received light from 0 - 100%, with the
minimum AD value from teaching as 0 and the maximum
Transmission side
as 100%.
■Light emitting power setting
Set the light emitting level.
- Address writer (ARW-04): Parameter 09
Variable
Details
0
High
1
Middle
2
Low
■ON Delay setting
Set the ON delay time.
- Address writer (ARW-04): Parameter 10
Variable
Unit
0 - 999
100ms
■OFF Delay setting
Set the OFF delay time.
- Address writer (ARW-04): Parameter 11
Variable
Unit
0 - 999
100ms
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
Default: 0
■One Shot setting
Set the One Shot time.
- Address writer (ARW-04): Parameter 12
Variable
0 - 999
■Address/Parameter automatic setting (base unit only)
Automatically set the address and parameter.
- Address writer (ARW-04): Parameter 17
Variable
0
Automatic setting disabled
1
Automatic setting for address only
2
Automatic setting for parameter only
* Linked to base unit's parameters.
3
Address/Parameter automatic setting
This functional automatically re ects in the extension unit the addresses and
parameters set in the base unit.
If this automatic setting mode is enabled (value 1, 2, or 3), addresses and
parameters set to the base unit are automatically alloted to the extension unit.
Example)
For parameter 17 value 1
■7-segment display orientation switch setting (base unit only)
This function ips the 7-segment display by 180°.
This is convenient when, depending on the orientation of this product, the
numbers are dif cult to read.
- Address writer (ARW-04): Parameter 18
Variable
0
Normal display
1
180° ipped display
Fiber side
-L*F1011 8/11-
Unit
Default: 0
100ms
Details
Default: 0
"3"
Allot
"2"
"1"
Setting address
"0"
Details
Default: 0
0: Normal display
1: 180° ipped display
Extension
Extension
Extension
Base
Transmission side