3.2 Lubricating

16
For lubricating the machine use only ESSO SP-NK 10 lubricating oil.
SP-NK 10 is available from the DÜRKOPP ADLER AG sales offices.
Checking the oil level in the hook drive housing
The oil level in the hook drive housing 2 should not fall below the
lower, long marking line on the viewing glass when the machine is
tilted to the back.
If necessary, fill oil to the upper marking line.
For this screw out the oil fill screw 1.
Checking the oil level in the reservoir
The reservoir 3 supplies all bearing positions of the machine except
for the hook drive via a central oil wick lubrication.
The oil level in the reservoir 3 should not fall below the "Min" mark
with the machine head upright.
If necessary, fill oil through the holes in the viewing glass up to the
"Max" mark.