Anztec PS 200 Manuel d'installation et d'utilisation - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Anztec PS 200. Anztec PS 200 6 pages.
Anztec PS200 Installation/Operating Guide V1.2
Coin Mech Installation
Warning – Never plug or un-plug the coin mech into/out of the 10 pin connector when
the PS200 is powered-up. Always remove power from the PS200 before connecting or
disconnecting the coin mech.
Plug the coin mech into the 10 pin coin mech connector. The PS200 accepts pulses on the
accumulator channel (channel 6) and integrates these with pulses coming from the credit card
terminal. These summed pulses are then used to drive a dry contact relay output which is available
for use on the terminal block connector pins 3 and 4 (Pulse Out). The green LED flashes to indicate
that the relay output has been activated.
Connection to Timer/Controller
The host timer/controller is connected via the blue terminal block.
Terminal block pins are numbered from right to left. Labels on PCB and functionality are as follows:
Pin
PCB Label
Function
No.
1
IN+
24VAC Hot or DC Supply Positive
2
IN-
24VAC Common or DC Supply Negative
3
PUL-OUT
Dry contact relay terminal 1
4
PUL-OUT
Dry contact relay terminal 2
5
P-IN
Pulse Input From Card Terminal
6
+12V
12V Output to Power Card Terminal
7
-12V
GND Output to Power Card Terminal
8
-12V
GND Output to Power Card Terminal