Installation
Perform by Qualified Personnel only.
1
Disconnect the cable from the negative battery terminal or
as directed by OEM truck manual.
2
Locate and install the solenoid valve and spacer on
the truck cowl using customer supplied .25 in. (6 mm)
fasteners. Watch for clearance when the mast is tilt all the
way back. The valve is being installed in the ROTATE line
from the auxiliary valve to the attachment.
IMPORTANT: The valve must be installed in the ROTATE
circuit.
3
Connect control valve port 1 to the supply hose going to
the attachment rotate drive valve.
4
Connect solenoid valve port 2 to the supply hose from the
truck auxiliary valve ROTATE line.
IMPORTANT: Verify by visual test, Installation steps 2, 3
and 4.
2
Mount
Solenoid
Valve
AC1013.eps
Hoist
Control
Valve
Truck
Hydraulic
Pump
GA0436.eps
2
Valve mounting holes:
0.25 in. or M6 thread
Attachment
Rotate Drive
Valve
Solenoid
Valve
1
2
Rotate
Auxiliary
Valve
Truck
Relief
Valve
2
1
Remove cable from
negative battery terminal
2.10 in.
2.10 in.
(53 mm)
(53 mm)
AC2048.eps
1.62 in.
1.62 in.
(41 mm)
(41 mm)
3
CW
CCW
Install
attachment
supply hose
to Port 1
4
Install auxiliary
valve hose to
Part 2
Truck
Tank
AC0447.eps
4.80 in.
4.80 in.
(122 mm)
(122 mm)