Danfoss 088U0215 Instruction - Page 5
Parcourez en ligne ou téléchargez le pdf Instruction pour {nom_de_la_catégorie} Danfoss 088U0215. Danfoss 088U0215 16 pages. Cf-rf room thermostat with infrared floor sensor
Instruction
2. Installation
Note: Assignment of Room Thermostats to Master Controller
should be within a distance of 1.5 m.
Activate Install mode on Master Controller (fig. 1)
• Use the menu selection button to select the Install
mode. Install LED flashes.
• Activate Install mode by pressing OK. Install LED
goes ON.
Activate Install mode on room thermostat
• Press the push button . LED and flicker during
communication.
Select output on Master Controller
• All available output LEDs on Master Controller light
up, and the first one flashes.
• Press output selection button to select desired
output (flashes). Accept with OK .
• All output LEDs go OFF. Selected output stays ON
shortly.
Room thermostat installation status
• Satisfactory: LED goes OFF.
• Not satisfactory: LED flashes 5 times.
Note: A room thermostat can be assigned to several outputs
if needed by repeating the installation process.
© Danfoss 05/2011
CF-RF Room Thermostat with Infrared Floor Sensor
VIUHR402
Danfoss Heating Solutions
5