Danfoss ECtemp 532 Manuel d'installation - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Danfoss ECtemp 532. Danfoss ECtemp 532 16 pages.
Danfoss ECtemp 532
2.
Connect the thermostat according to the connection
diagram.
The screen of the heating cable must be connected
to the earth conductor of the power supply cable by
using a separate connector.
Note: Always install the floor sensor in a conduit in
the floor.
3.
Set the maximum floor temperature between 20° and
50°C by turning the screw with temperature indica-
tions in the upper left corner.
4.
Mount and reassemble the thermostat:
• Fasten the thermostat to a flush-mounting box
or a surface-mounting box by driving the screws
through the holes in each side of the thermostat.
• Install the frame and front cover in the reverse
order of disassembly.
5.
Turn on the power supply.
Installation Guide
N
L
N
L
LOAD
LOAD
Mains
Max. Load
220-240V~
15 (1) A
D532
NTC
IP31
-10T30
9