2. GROUNDING TEST

2.1 Make
sure
that
switched OFF. Attach the Analyser
clips onto the battery terminal posts
[Red to (+) and Black to (-)] the unit
will
power
up
display LCD screen as shown below.
BATTERY
ELECTRICAL
SYSTEM ANALYSER
2.2 It will run through a self-test and
when completed it displays the Main
Menu as shown below:
Select Test  
New: Clear Memory
Continue Test . . .
Last Test Result
2.3 Pressing DOWN key once will scroll
down to the "Grounding Test"
Battery Test
Grounding Test
Starter Test
Alternator Test
2.4 Pressing
ENTER
the display as follows.
Grounding Test:
Enter
Press
Start
the
engine
is
and
momentarily
BESA 11
key will proceed to
to
2.5 Press
ENTER
key again, it will start
analysing.
Analysing . . .
Please Wait!
▌▌▌▌▌▌▌▌
2.6 Once it has finished analysing, it will
prompt you with an instruction stating
that you should unclamp the black
battery clip from the battery negative
terminal and clamp it to the engine
body within 15 seconds time limit.
To clamp
15 sec
Black clip to
Engine body,
then press
NOTE:
15 seconds
is given to establish
the contact to the engine body failing
which the data obtained earlier will be
lost. Then you need to repeat the whole
testing procedures again.
2.7 Once the Black clip is clamped onto
the engine body it will start analysing.
Analysing . . .
Please Wait!
▌▌▌▌▌▌▌▌
Enter