Apogee Symphony I/O Mk II SoundGrid Manuel de l'utilisateur - Page 14

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Apogee Symphony I/O Mk II SoundGrid. Apogee Symphony I/O Mk II SoundGrid 20 pages. For units equipped with the wsg option card

Apogee Symphony I/O Mk II SoundGrid Manuel de l'utilisateur
6. Reset Trim​ - Restores the Trim controls to 0.0.

Inputs Tab

Settings for Symphony I/O Mk II's analog and digital inputs are found on the Inputs page
1. Analog Level​ type selector - Set the analog level for each A/D conversion channel.
○ Choose ​ + 4 dBu​ when connecting to "pro" gear with outputs at a +4 dBu nominal level.
○ Choose ​ - 10 dBV​ when connecting to "semi-pro", hi-fi or musical instrument gear with outputs at a -10
dBV nominal level.
2. Digital Ref​ level - Decides the reference point at which this channel's analog input signal will be
converted to a digital signal.
3. Soft Limit​ - Apogee's proprietary analog circuit which attenuates transient peaks of the input signal at a
threshold of -4dBfs before conversion to digital.
4. Meter Level Readout​ - Provides a reading of the analog input meter to an accuracy of 0.1 dB.
5. SPDIF Replaces​ - To use the S/PDIF Coax input, itʼs necessary to select
another analog or digital channel pair which the S/PDIF Coax input will replace.
Use this drop down menu to select the channel pair to be replaced.