Window SET and Manual Adjust
Moves sensing window center value up or down to make adjustments
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
- GREEN display shows the sensing window center value
- 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH Selection must be programmed to wind SEt (see
1. Enter Adjust Mode
Method
SET Button 8
Remote Input 9
2. SET Sensing Condition
Method
SET Button
Remote Input
1. Return to RUN Mode
Method
SET Button
Remote Input
SET Button: 0.04 seconds ” "Click" ” 0.8 seconds
8
Remote Input: 0.04 seconds ” T ” 0.8 seconds
9
See
Troubleshooting
on page 16 for more explanation of the % Offset displayed after the Window SET method.
10
Action
Set Mode switch to ADJ
No action required; sensor is ready for Window SET method
Action
Present sensing condition
Click the SET Navigation key
Present sensing condition
Single-pulse the remote input
Action
Move Mode switch to Run
No action required; sensor returns to Run
mode automatically
Window SET (during RUN mode)
Upon sensor power-up, Window Center is displayed
Upper Threshold
Displayed
Figure 5. Upper and Lower Thresholds
Program
Mode)
Display: Red - Signal Level;
Threshold Condition Accepted
Displays read "wInd SEt" then
alternate "PASS" with % Offset 10 ;
Sensor returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "wInd SEt" then
alternate "FAIL" with minimum %
Offset 10 for sensing condition; Sensor
returns to Adjust mode
Display: Red - Signal Level;
display upper and lower thresholds)
Window Center
Lower Threshold
Displayed
Displayed
9
Result
Green - Threshold
Result
Result
Green - Window Center
(see Figure 5 for instructions on how to