Datalogic S70 Manuale - Pagina 9

Sfoglia online o scarica il pdf Manuale per Accessories Datalogic S70. Datalogic S70 18. Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Anche per Datalogic S70: Manuale di avvio rapido (10 pagine)

Datalogic S70 Manuale
Window SET and Manual Adjust
Moves sensing window center value up or down to make adjustments
Slide Mode switch to ADJ to enter Adjust mode
Press "+" to increase; press "-" to decrease
- GREEN display shows the sensing window center value
- 2 seconds after adjustment, the GREEN display will flash 3 times to confirm
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH Selection must be programmed to wind SEt (see
1. Enter Adjust Mode
Method
SET Button 8
Remote Input 9
2. SET Sensing Condition
Method
SET Button
Remote Input
1. Return to RUN Mode
Method
SET Button
Remote Input
SET Button: 0.04 seconds ” "Click" ” 0.8 seconds
8
Remote Input: 0.04 seconds ” T ” 0.8 seconds
9
See
Troubleshooting
on page 16 for more explanation of the % Offset displayed after the Window SET method.
10
Action
Set Mode switch to ADJ
No action required; sensor is ready for Window SET method
Action
Present sensing condition
Click the SET Navigation key
Present sensing condition
Single-pulse the remote input
Action
Move Mode switch to Run
No action required; sensor returns to Run
mode automatically
Window SET (during RUN mode)
Upon sensor power-up, Window Center is displayed
Upper Threshold
Displayed
Figure 5. Upper and Lower Thresholds
Program
Mode)
Display: Red - Signal Level;
Threshold Condition Accepted
Displays read "wInd SEt" then
alternate "PASS" with % Offset 10 ;
Sensor returns to Adjust mode
T
Threshold Condition Not Accepted
Displays read "wInd SEt" then
alternate "FAIL" with minimum %
Offset 10 for sensing condition; Sensor
returns to Adjust mode
Display: Red - Signal Level;
display upper and lower thresholds)
Window Center
Lower Threshold
Displayed
Displayed
9
Result
Green - Threshold
Result
Result
Green - Window Center
(see Figure 5 for instructions on how to