Datalogic POWERSCAN PBT7100 guide Manuel de référence rapide - Page 15

Parcourez en ligne ou téléchargez le pdf Manuel de référence rapide pour {nom_de_la_catégorie} Datalogic POWERSCAN PBT7100 guide. Datalogic POWERSCAN PBT7100 guide 20 pages. Cordless imaging reader
Également pour Datalogic POWERSCAN PBT7100 guide : Manuel de référence rapide (16 pages)

Datalogic POWERSCAN PBT7100  guide Manuel de référence rapide

Defaults

For your convenience, standard factory defaults
types. For more details or to change these settings, reference the Product Reference Guide (PRG).
RS-232 Standard Default Settings:
abled, no Intercharacter Delay, Beep on ASCII BEL disabled, Beep On Not On File enabled, ACK
Character = 'ACK', NAK Character = 'NAK', ACK NAK Timeout Value = 600ms, ACK NAK
Retry Count = 3, ACK NAK Error Handling = Ignore, Indicate Transmission Failure enabled, Dis-
able Reader Command = 'D', Enable Reader Command = 'E'.
Wand Emulation Standard Default Settings:
Quiet Zones & Spaces High - Bars Low, No Label Symbology Conversion, Transmit Noise = Dis-
abled.
OEM/IBM Standard Default Settings:
Transmit Labels in Code 39 Format = OEM Standard Format, 46xx Number of Host Resets = 6.
USB Standard Default Settings:
Keyboard Standard Default Settings (Keyboard AT):
Lock= OFF, Numlock Key =Unchanged, Send Control Characters = Disabled, Wedge Quiet Inter-
val = 100ms, No Wedge Intercode Delay.

Enabled Symbologies

UPC-A, UPC-E, EAN 13, EAN 8 — without add-ons, Check Character Transmission
enabled, no Expansion, Minimum Reads = 1 (except In-Store Minumum Reads = 2), Sys-
tem Number Transmission = enabled, 2D Components = disabled, EAN 8 Guard Inser-
tion/Substitution Options = disabled (except EAN 8 Guard Substitution), Stitching =
disabled.
Code 39 — Check Character Calculation/Transmission enabled, Start/Stop Character dis-
abled, Full ASCII disabled, Quiet Zones = auto, Minimum Reads = 1, Decoding Level and
Aggressiveness = 3, Variable Length Control, Length One = 2, Length Two = 50, Interdigit
Ratio = 4, Character Correlation = Disabled, Stitching is enabled.
Code 128 — No Expansion, Check Character Transmission enabled, SubCode Change not
transmitted, Quiet Zones = Auto, Minimum Reads = 1, Decoding Levels and Aggressive-
ness = 3, Variable Length Control, Length One = 1, Length two = 80, Character Correla-
tion = disabled, Stitching = enabled.
Interleaved 2 of 5 — Zero Pattern and Check Character Calculation = disabled, Check
Character Transmission = enabled, Minimum Reads = 1, Decoding Levels and Aggressive-
ness = 3, Variable Length Control, Length One = 12, Length Two = 100, Character Corre-
lation and Stitching = disabled.
1. Applicable only when the reader is connected to a host via the Base Station.
Quick Reference Guide
1
are shown here for each of the major interface
9600 Baud, no Parity, 1 Stop Bit, Handshaking dis-
Wand Idle State = Low, Wand Polarity =
OEM-USB Device Usage = Table Top Reader,
USB Keyboard Speed = Fast (1ms).
Defaults
Country Mode = U.S., Caps
13