Defaults

For your convenience, standard factory defaults
types. For more details or to change these settings, reference the Product Reference Guide (PRG).
RS-232 Standard Default Settings:
abled, no Intercharacter Delay, Beep on ASCII BEL disabled, Beep On Not On File enabled, ACK
Character = 'ACK', NAK Character = 'NAK', ACK NAK Timeout Value = 600ms, ACK NAK
Retry Count = 3, ACK NAK Error Handling = Ignore, Indicate Transmission Failure enabled, Dis-
able Reader Command = 'D', Enable Reader Command = 'E'.
Wand Emulation Standard Default Settings:
Quiet Zones & Spaces High - Bars Low, No Label Symbology Conversion, Transmit Noise = Dis-
abled.
OEM/IBM Standard Default Settings:
Transmit Labels in Code 39 Format = OEM Standard Format, 46xx Number of Host Resets = 6.
USB Standard Default Settings:
Keyboard Standard Default Settings (Keyboard AT):
Lock= OFF, Numlock Key =Unchanged, Send Control Characters = Disabled, Wedge Quiet Inter-
val = 100ms, No Wedge Intercode Delay.

Enabled Symbologies

UPC-A, UPC-E, EAN 13, EAN 8 — without add-ons, Check Character Transmission
enabled, no Expansion, Minimum Reads = 1 (except In-Store Minumum Reads = 2), Sys-
tem Number Transmission = enabled, 2D Components = disabled, EAN 8 Guard Inser-
tion/Substitution Options = disabled (except EAN 8 Guard Substitution), Stitching =
disabled.
Code 39 — Check Character Calculation/Transmission enabled, Start/Stop Character dis-
abled, Full ASCII disabled, Quiet Zones = auto, Minimum Reads = 1, Decoding Level and
Aggressiveness = 3, Variable Length Control, Length One = 2, Length Two = 50, Interdigit
Ratio = 4, Character Correlation = Disabled, Stitching is enabled.
Code 128 — No Expansion, Check Character Transmission enabled, SubCode Change not
transmitted, Quiet Zones = Auto, Minimum Reads = 1, Decoding Levels and Aggressive-
ness = 3, Variable Length Control, Length One = 1, Length two = 80, Character Correla-
tion = disabled, Stitching = enabled.
Interleaved 2 of 5 — Zero Pattern and Check Character Calculation = disabled, Check
Character Transmission = enabled, Minimum Reads = 1, Decoding Levels and Aggressive-
ness = 3, Variable Length Control, Length One = 12, Length Two = 100, Character Corre-
lation and Stitching = disabled.
1. Applicable only when the reader is connected to a host via the Base Station.
Quick Reference Guide
1
are shown here for each of the major interface
9600 Baud, no Parity, 1 Stop Bit, Handshaking dis-
Wand Idle State = Low, Wand Polarity =
OEM-USB Device Usage = Table Top Reader,
USB Keyboard Speed = Fast (1ms).
Defaults
Country Mode = U.S., Caps
13