2.2. Connect Powered Device
Connect the device to be powered ON and OFF to the IEC receptacle
marked Switched Outlet. An IEC 320 to North American (NEMA 5-15)
power cord is included for connecting the iBoot-G2 outlet to the device
to be controlled.
Make sure that the combined load of all controlled
devices does not exceed 12 Amps for 105-125VAC or 10
Amps for 210-240VAC.
2.3. Connect Power Mains
Connect the supplied power cord to the connector labeled AC Input, and
the other end to your AC source. If a power cord with a different terminating plug is required, be sure it is properly
rated and meets all the required local electrical standards.
The iBoot-EXP had two LED indicators.
LED
OFF
OK - Green
No Power Connection from iBoot-G2+ or 12VDC
source. The PWR LED is not indicative of the
Power outlet status
PWR - Red
When OK LED ON = Power OFF to the Outlet
When OK LED OFF = Not Valid Indication of
Power OFF. Power to the outlet may be ON.
V100921e
Fig. 4 Connect
Power Mains

3. LED Indicators

iBoot-EXP
Fig. 5 Other Power Cords
Sourced Locally
ON
Power to drive the iBoot-EXP is connected.
Power Outlet On
Fig. 3 Connect
Powered Device