Dataprobe iBoot-Exp Manual - Halaman 2
Jelajahi secara online atau unduh pdf Manual untuk Perangkat Keras Komputer Dataprobe iBoot-Exp. Dataprobe iBoot-Exp 5 halaman. Expansion module for iboot
2.2. Connect Powered Device
Connect the device to be powered ON and OFF to the IEC receptacle
marked Switched Outlet. An IEC 320 to North American (NEMA 5-15)
power cord is included for connecting the iBoot-G2 outlet to the device
to be controlled.
Make sure that the combined load of all controlled
devices does not exceed 12 Amps for 105-125VAC or 10
Amps for 210-240VAC.
2.3. Connect Power Mains
Connect the supplied power cord to the connector labeled AC Input, and
the other end to your AC source. If a power cord with a different terminating plug is required, be sure it is properly
rated and meets all the required local electrical standards.
The iBoot-EXP had two LED indicators.
LED
OFF
OK - Green
No Power Connection from iBoot-G2+ or 12VDC
source. The PWR LED is not indicative of the
Power outlet status
PWR - Red
When OK LED ON = Power OFF to the Outlet
When OK LED OFF = Not Valid Indication of
Power OFF. Power to the outlet may be ON.
V100921e
Fig. 4 Connect
Power Mains
3. LED Indicators
iBoot-EXP
Fig. 5 Other Power Cords
Sourced Locally
ON
Power to drive the iBoot-EXP is connected.
Power Outlet On
Fig. 3 Connect
Powered Device
Page 2