Aircommand Kingfisher Installation, entretien courant, spécifications, dépannage, garantie - Page 6

Parcourez en ligne ou téléchargez le pdf Installation, entretien courant, spécifications, dépannage, garantie pour {nom_de_la_catégorie} Aircommand Kingfisher. Aircommand Kingfisher 7 pages.

Height:
595mm
Width:
470mm
Depth
500mm
Weight:
52Kg
Rated Voltage:
Cooling output:
Heating Output:
Max. Current:
Locked Rotor Current:
Rated Power Input:
Refrigerant:
Charge
Air Volume Off Evaporator 150l/s
Unit will not energise
No green light on the facia
signifying the compressor is
not running
Insufficent Cooling
Insufficent Heating

UNIT SPECIFICATIONS

230V 50Hz
2.5Kw
2.5Kw
4.8Amps
20Amps
1150W
R22
830grams
TROUBLE SHOOTING
Not plugged in
Circuit breaker open
Handheld remote control has flat
batteries or incorrectly inserted
Control plug behind facia not
pushed together
Still in the 3 minute time delay
Thermostat set incorrectly
Thermostat set too high
Inside fan speed too low
Area to be cooled is too great
Thermostat set too low
In very cold conditions the unit
may be in de-ice mode
Area to be heated is too great
Page 6 of 7
Revised 13/7/05
More information https://www.caravansplus.com.au
Check plug at GPO
Reset at van's board
Replace batteries or turn on
unit manually (see fig 9a)
Remove facia assembly and
ensure plug is correctly
assembled
Wait 3 minutes
Reset handheld remote
control
Adjust the thermostat
Set fan speed to high
Reduce the heat load by better
insulation, window shades
etc.
Adjust the thermostat
Wait for unit to resume
operation
Better insulation and/or
reduce air infiltration