Setup

Required Equipment

ACT4529EVK1 EVK
Power supply – 40V @ 4A for full power operation
Oscilloscope – >100MHz, >2 channels
Loads –Electronic/resistive load with 3.5A minimum current capability.
Digital Multimeters (DMM)

Hardware Setup

1. Connect a DC Power to the VIN and GND jumpers on the left side of the EVK.
2. Using a USB Type C connector, connect the EVK output to an electronic load.
3. Do not connecting anything to J2. J2 is a programming header.
Innovative Power
TM
TM
is a trademark of Active-Semi.
ActiveSwitcher
DC
Power
Figure 3 – EVK Setup