Active-semi ACT4529EVK1 사용자 설명서 - 페이지 2
{카테고리_이름} Active-semi ACT4529EVK1에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Active-semi ACT4529EVK1 18 페이지. Usb type c car charger solution
Setup
Required Equipment
ACT4529EVK1 EVK
Power supply – 40V @ 4A for full power operation
Oscilloscope – >100MHz, >2 channels
Loads –Electronic/resistive load with 3.5A minimum current capability.
Digital Multimeters (DMM)
Hardware Setup
1. Connect a DC Power to the VIN and GND jumpers on the left side of the EVK.
2. Using a USB Type C connector, connect the EVK output to an electronic load.
3. Do not connecting anything to J2. J2 is a programming header.
Innovative Power
TM
TM
is a trademark of Active-Semi.
ActiveSwitcher
DC
Power
Figure 3 – EVK Setup
2
UG105
Rev 1.0, 20-July-17
DC
Load