POWERLINE CARRIER DEVICES WORKSHEET FOR * 80, and * 81.
Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.

80 OUTPUT DEVICES

Fill in the required data on the worksheet on below and follow the programming procedure in the Installation Instructions as
you enter the data during the displays and prompts that appear in sequence.
Note:
Field 25 must be programmed with a House Code.
DEVICE
ACTION
NUMBER
(aa)
01
P.L.C.D.*
02
P.L.C.D.*
03
P.L.C.D.*
04
P.L.C.D.*
05
P.L.C.D.*
06
P.L.C.D.*
07
SYSTEM
P.L.C.D.*
08
SYSTEM
P.L.C.D.*
*
P.L.C.D. = Powerline Carrier Device (X-10).
Where:
A = DEVICE ACTION
ET = EVENT TYPE
Z L = ZONE LIST 1, 2, or 3 (from Field 81) or 0 = Not Used.
ZT = ZONE TYPE/SYSTEM OPERATION Choices for Zone Types are:
00 = Not Used
01 = Entry/Exit#1
02 = Entry/Exit#2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
Choices for System Operation are:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Burglary Alarm
36 = *At Bell Timeout
Note: In normal operation mode:
For Devices 1-6:
Function + Lights On + N
Function + Lights Off + N
S T A R T
either or both
EVENT
ZONE
ZONE TYPE
TYPE
LIST
SYST OP'N
(et)
(zl)
(zt)
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.
"STOP" RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It
NOTE: Do not assign zones with zone types 20, 21, or 22 to a zone list.
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire Zone
10 = Interior w/Delay
24= Silent Burglary
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
42 = System Battery Low
43 = Communication Failure
52 = Kissoff
58 = Duress
either or both
RESTORE
ZONE LIST
(zl)
need not be same list as used for START.
Note: Any zone in "ZT" going into alarm,
For Devices 7 and 8:
Code + Function + 4 + N
Code + Function + 7 + N
14 –
S T O P
ZONE TYPE
/SYST OP'N
(zt)
fault, or trouble will activate device.
Any zone of that type that restores
will stop device action.
* Or at Disarming, whichever occurs
earlier.
N = device (unit) number
(Entry starts Device N)
(Entry stops Device N)