ADEMCO Q16 Instructions pour l'utilisateur - Page 4

Parcourez en ligne ou téléchargez le pdf Instructions pour l'utilisateur pour {nom_de_la_catégorie} ADEMCO Q16. ADEMCO Q16 7 pages.

ADEMCO Q16 Instructions pour l'utilisateur
alarm control panel will send out a shot and a long sound of "B" to show
users' operation is correct.
20, The Neighbor alarm instead function On/Off
.;
Route: "Program+0+*+17+(0 or l)+Program". the alarm control panel will
send out a shot and a long sound of "B" to show users' operation is correct.
o
means close,l means allow. When the phone line been cut illegally, It will
send the alarm message to the alann center through neighbor, of course,
it
must to set a correct neighbor's ID and the Neighbor alarm instead function
IS
on.
21, The Times for dial again when communicate the alarm center failed
Route: "Program+0+*+07+? ? +Program" , the alarm control panel will send
out a shot and a long sound of"B" to show users' operation is correct. The
??
means the times, For five times, you have to input 05.
22, The Times for try to dial the manual telephone of alarm center
Route: "Program+O+*+ 11 +? ? +Program", the alarm control panel will send out
a shot and a long sound of "B" to show users' operation is correct. The
??
means the times, For five times, you have to input 05.The maximum times
is 30.
.
;
23, When the communication failed, Set the interval to dial again
Route: "Program+0+*+8+? ? +Program", the ~arm control panel will send out
a shot and a long sound of "B" to show users' operation is correct. The
??
means the minutes, For 10 minutes, you have to input 10.The maximum is
30 minutes. '
24, How to setting the quantity of Ademoco alarm phones
Route: "Program+0+*+9+? ? +Program", the alarm control panel will send out
a shot and a long sound of "B" to show users' operation is correct. The
??
means the quantity, For set 3 Ademoco alarm phones, you have to input 03.
The maximum is 5.
6
25, Setting the Ademco Parameters
Please refer to the (QI6-ADEMCO COMMANDS)
When the key of ABCDEF is concerned please input the following respectively instead
(O=A,*=B,#=C, arm=D, disarm =E, emergency/panic =F)o
21-28 is the code of bypass / bypass recovery detectors. Command format:
Program+0+*+2N+XX+YY+ZZ+Program. N is the code of defense zone. XX is the
code of alarm. YY is the code of bypass.
iz
is the code of bypass recovery. Every
zone can be armed or disarmed separately (The data of disarm separately will not
memory after a power cut), so different zones have different code. For example: if the
door sensor is in the 3rd zone. If its code of alarm is 53, code of bypass is 62, and code
of bypass recovery is 89, please input Program+0+*+23+53+62+89+Program, A
long and short beep means the operation is successful.
Protocol of communication about the alarm phone : When alarm the system will
first auto-dial the two alarm telephones (telephone of alarm monitoring center,
according to the set of Item 24) you pre-set. When one call is answered by the alarm
monitoring center, the alarm call will be passed to manual telephone otherwise the
system will dial the 2 pre-set alarm telephone regularly until it reaches the times which
set by Item 21, the alarm call will be passed to manual telephone. When somebody
answer the phone, he can hear the record and can do the operation as Item 30. You
must remember to press # to end the operate, otherwise it will continue to dial the
next telephone numbers pre-seted.
If the system dial the manual telephone reached
the times pre-set in Item 22, and no one answer the phone, the system will exit the
operation. If the communication to the alarm center failed, the system will resend the
alarm data to the alarm center after several minutes which set by Item 23. According to
the Item 24, you can set more alarm phones for many users, If that the probability of
success to connect with alarm center will be high.
26, Original state of system parameter:
Telephone line anti-cut function on; keypad tone on ;sounded alarm; Time of siren
hooting is 2 minutes;Call in telephone ring times is 6; The time for extend the arm is 0
seconds; The time for alarm extend the alarm is 20 seconds; No alarm telephone
numbers; ID code for network is FFFF: 30 times to call manual telephone.
7