Celec ES-09 Manuel d'installation sur le terrain - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel d'installation sur le terrain pour {nom_de_la_catégorie} Celec ES-09. Celec ES-09 10 pages.

ES-09
Field Installation Manual
Connection Type#2
Use these instructions
If 63 Amp circuit breaker is unavailable, existing blanks are available.
ES-09 unit is designed for use with Customer Main Breaker Panel Single Phase 240V AC
up to 400 Amp.
ES-09 units should be mounted with four appropriate sized fasteners before connect to Main Breaker
Panel.
1. Remove Main Panel covers exposing internal wiring and breakers.
2. Remove existing 2 Pole breaker blanks and install new 2 Pole 63 Amp circuit Breakers.
3. For rest of connection follow the Connection type#1 on page 5.
______________________________________________________________________________________
-7-