2gig Technologies 2GIG BRDG1 900 Instructions d'installation - Page 3

Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} 2gig Technologies 2GIG BRDG1 900. 2gig Technologies 2GIG BRDG1 900 4 pages. Bridge ip communicator

A summary screen displays the following information:
• Network Configuration. The network type configuration.
• IP Address. The IP Address for the Go!Bridge. This is a 32‐bit 
numeric address that identifies the device on the network.
• Subnet Mask. The subnet mask for the network. All devices 
that are joined to a network belong to a subnetwork.
• Gateway. The IP Address for the access point to the external 
network. Typically, this is the IP Address of the local network 
router or node that control traffic for your ISP.
• MAC Address. This is the Media Access Control (MAC) 
Address. It is a physical address that is encoded to the 
Go!Bridge during the manufacturing process. 
Testing
The Go!Bridge tests the network connection to the third‐party 
monitoring service. A report shows if Go!Bridge has successfully 
connected (or failed to connect) to the external server.
Registration
To register the Go!Bridge with the monitoring service, refer to your 
specific provider's registration instructions. 
SPECIFICATIONS
Wireless Signal Range
500 ft (152.4 m), open air, with Wireless Control 
Panel
Silicon Labs SI1001‐E‐GM2
Transceiver
Transceiver Frequency
25 channel frequency‐hopping spread spectrum, 
403 kHz channel spacing (910.2‐920.275 MHz)
Modulation Type
GFSK modulation, 128 kpbs
+19dBm Maximum
RF Power
Ethernet
10/100 BaseT
Dimensions (L x W x H)
6.24 x 4.5 x 1 in (159 x 114 x 25 cm)
Weight
9.6 oz
Housing Material
Cycoloy™ Resin C2800 (Rated to UL 94 V‐0: 
Flammability Standard)
Color
White
32° F to 120.2° F, (0° C to +49° C)
Operating Temperature
Relative Humidity
5‐95% Non‐Condensing
5VDC
Operating Voltage
Certification
ETL, FCC Part 15, and Industry Canada
IMPORTANT NOTE
Should the local network lose Internet access due to a power outage 
or interruption, the Go!Bridge is not equipped with a backup battery 
system. To best prepare for power failures and to ensure the security 
system maintains Internet access with the monitoring service for life‐
safety communications during power failures, the local network must 
have a dedicated Uninterrupted Power Supply (UPS) or backup battery 
solution from a third‐party manufacturer in place. Linear LLC does not 
supply, provide, recommend, or test the Go!Bridge with any UPS or 
battery backup solution. It is also assumed that owner's Internet 
Service Provider (ISP) maintains a backup battery (or power 
generator) for their remote network equipment. 
REGULATORY INFORMATION
Wireless Product Notice
Radio controls provide a reliable communications link and fill an 
important need in portable wireless signaling; however, there are 
some limitations which must be observed.
• For United States Installations Only: The radios are required to 
comply with FCC Rules and Regulations as Part 15 devices. As 
such, they have limited transmitter power and therefore 
limited range (approximately 400 ft.).
• A receiver cannot respond to more than one (1) transmitted 
signal at a time and may be blocked by radio signals that occur 
on or near their operating frequencies, regardless of code 
settings.
• Changes or modifications to the device may void FCC 
compliance.
• Infrequently used radio links should be tested regularly to 
protect against undetected interference or fault.
• A general knowledge of radio and its vagaries should be gained 
prior to acting as a wholesale distributor or dealer, and these 
facts should be communicated to the end users.
ETL Listed
This device has been tested by Intertek and is in 
compliance with UL 1023: Household Burglar‐Alarm 
System Units in the United States and Canada. 
FCC Part 15 Notice
This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions:
1
This device may not cause harmful interference, and 
2
This device must accept any interference received, including 
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits 
for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates 
and can radiate radio frequency energy and, if not installed and used 
in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one (1) 
or more of the following measures.
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for 
help
Any changes or modifications not expressly approved by the party 
responsible for compliance could void the user's authority to operate 
the equipment.
Les changements ou modifications non approuvés expressément par 
la partie responsable de la conformité pourrait annuler l'autorité de 
l'utilisateur à faire fonctionner l'équipement.
Industry Canada (IC) Compliance
This device complies with Industry Canada license‐exempt RSS 
standard(s). Operation is subject to the following two conditions: (1) 
this device may not cause interference, and (2) this device must accept 
any interference, including interference that may cause undesired 
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada 
applicables aux appareils radio exempts de licence. L'exploitation est 
autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas 
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage est 
susceptible d'en compromettre le fonctionnement.
Repairs to certified equipment should be made by an authorized 
Canadian maintenance facility designated by the supplier. Any repairs 
or alterations made by the user to this equipment, or equipment
Copyright © 2014 Linear LLC