A summary screen displays the following information:
• Network Configuration. The network type configuration.
• IP Address. The IP Address for the Go!Bridge. This is a 32‐bit
numeric address that identifies the device on the network.
• Subnet Mask. The subnet mask for the network. All devices
that are joined to a network belong to a subnetwork.
• Gateway. The IP Address for the access point to the external
network. Typically, this is the IP Address of the local network
router or node that control traffic for your ISP.
• MAC Address. This is the Media Access Control (MAC)
Address. It is a physical address that is encoded to the
Go!Bridge during the manufacturing process.
Testing
The Go!Bridge tests the network connection to the third‐party
monitoring service. A report shows if Go!Bridge has successfully
connected (or failed to connect) to the external server.
Registration
To register the Go!Bridge with the monitoring service, refer to your
specific provider's registration instructions.
SPECIFICATIONS
Wireless Signal Range
500 ft (152.4 m), open air, with Wireless Control
Panel
Silicon Labs SI1001‐E‐GM2
Transceiver
Transceiver Frequency
25 channel frequency‐hopping spread spectrum,
403 kHz channel spacing (910.2‐920.275 MHz)
Modulation Type
GFSK modulation, 128 kpbs
+19dBm Maximum
RF Power
Ethernet
10/100 BaseT
Dimensions (L x W x H)
6.24 x 4.5 x 1 in (159 x 114 x 25 cm)
Weight
9.6 oz
Housing Material
Cycoloy™ Resin C2800 (Rated to UL 94 V‐0:
Flammability Standard)
Color
White
32° F to 120.2° F, (0° C to +49° C)
Operating Temperature
Relative Humidity
5‐95% Non‐Condensing
5VDC
Operating Voltage
Certification
ETL, FCC Part 15, and Industry Canada
IMPORTANT NOTE
Should the local network lose Internet access due to a power outage
or interruption, the Go!Bridge is not equipped with a backup battery
system. To best prepare for power failures and to ensure the security
system maintains Internet access with the monitoring service for life‐
safety communications during power failures, the local network must
have a dedicated Uninterrupted Power Supply (UPS) or backup battery
solution from a third‐party manufacturer in place. Linear LLC does not
supply, provide, recommend, or test the Go!Bridge with any UPS or
battery backup solution. It is also assumed that owner's Internet
Service Provider (ISP) maintains a backup battery (or power
generator) for their remote network equipment.
REGULATORY INFORMATION
Wireless Product Notice
Radio controls provide a reliable communications link and fill an
important need in portable wireless signaling; however, there are
some limitations which must be observed.
• For United States Installations Only: The radios are required to
comply with FCC Rules and Regulations as Part 15 devices. As
such, they have limited transmitter power and therefore
limited range (approximately 400 ft.).
• A receiver cannot respond to more than one (1) transmitted
signal at a time and may be blocked by radio signals that occur
on or near their operating frequencies, regardless of code
settings.
• Changes or modifications to the device may void FCC
compliance.
• Infrequently used radio links should be tested regularly to
protect against undetected interference or fault.
• A general knowledge of radio and its vagaries should be gained
prior to acting as a wholesale distributor or dealer, and these
facts should be communicated to the end users.
ETL Listed
This device has been tested by Intertek and is in
compliance with UL 1023: Household Burglar‐Alarm
System Units in the United States and Canada.
FCC Part 15 Notice
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1
This device may not cause harmful interference, and
2
This device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits
for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one (1)
or more of the following measures.
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for
help
Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate
the equipment.
Les changements ou modifications non approuvés expressément par
la partie responsable de la conformité pourrait annuler l'autorité de
l'utilisateur à faire fonctionner l'équipement.
Industry Canada (IC) Compliance
This device complies with Industry Canada license‐exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Repairs to certified equipment should be made by an authorized
Canadian maintenance facility designated by the supplier. Any repairs
or alterations made by the user to this equipment, or equipment
Copyright © 2014 Linear LLC
3