Autonics M5W Series Manuel - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Autonics M5W Series. Autonics M5W Series 3 pages. Panel meters (indicator)

Autonics M5W Series Manuel
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the speci昀椀ed model, follow the Autonics webstie.
M
5
W
-
❶ Input type
DV: DC voltage
DA: DC current
W: Power
T: Rotation
S: Speed
DI: Scaling (DC 4 - 20 mA)
Measurement Input Speci昀椀cations
Input type
Measurement
input
DV
DA
No mark
-
-
199.99
199.99 ㎂
mVDCᜡ
1
1.9999
1.9999 mA
VDCᜡ
2
19.999
19.999 mA
VDCᜡ
3
199.99
199.99 mA
VDCᜡ
4
300.0
1.9999 A
VDCᜡ
5
-
19.999 A
6
-
199.99 A
7
8
-
1999.9 A
-
-
DX
XX
Option
Option
01)  This speci昀椀cation is based on the transducer with 0 - 10 VDCᜡ output.
When the output of transducer is DC 4 - 20 mA or 1 - 5 VDCᜡ, use the scaling meter.
02) This speci昀椀cation is based on the tacho generator with 0 - 10 VDCᜡ or 0 - 10 VACᜠ output.
Product Components
• Product (+bracket)
-
❷ Measurement input
Refer to measurement input
speci昀椀cations.
01)
02)
02)
W
T
S
-
-
-
19999 m /
19999 rpm
min
199.99 W
0 - 10
0 - 10
VDCᜡ
VDCᜡ
1.9999 kW
-
-
19.999 kW
-
-
199.99 kW
-
-
1999.9 kW
-
-
-
-
-
-
-
-
-
-
-
-
DC input Option
-
-
Option
• Instruction manual
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
96
■ Bracket
54
DI
Cautions during Wiring
19999
• Unit: mm, Use terminals of size speci昀椀ed below.
-
-
-
≥3.5
≤7.0
-
-
Connections
-
INPUT
-
-
1
2
3
-
+
-
Option
HIGH
LOW
• Power option
8
6
7
24 - 70 VDCᜡ
12
■ Panel cut-out
20
8
4
5
6
7
SOURCE
100 - 240 VACᜠ 50 / 60 Hz
100
≥ 116
92
+ 0.8
0