Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the speci昀椀ed model, follow the Autonics webstie.
❶
M
5
W
-
❶ Input type
DV: DC voltage
DA: DC current
W: Power
T: Rotation
S: Speed
DI: Scaling (DC 4 - 20 mA)
Measurement Input Speci昀椀cations
Input type
Measurement
input
DV
DA
No mark
-
-
199.99
199.99 ㎂
mVDCᜡ
1
1.9999
1.9999 mA
VDCᜡ
2
19.999
19.999 mA
VDCᜡ
3
199.99
199.99 mA
VDCᜡ
4
300.0
1.9999 A
VDCᜡ
5
-
19.999 A
6
-
199.99 A
7
8
-
1999.9 A
-
-
DX
XX
Option
Option
01) This speci昀椀cation is based on the transducer with 0 - 10 VDCᜡ output.
When the output of transducer is DC 4 - 20 mA or 1 - 5 VDCᜡ, use the scaling meter.
02) This speci昀椀cation is based on the tacho generator with 0 - 10 VDCᜡ or 0 - 10 VACᜠ output.
Product Components
• Product (+bracket)
❷
-
❷ Measurement input
Refer to measurement input
speci昀椀cations.
01)
02)
02)
W
T
S
-
-
-
19999 m /
19999 rpm
min
199.99 W
0 - 10
0 - 10
VDCᜡ
VDCᜡ
1.9999 kW
-
-
19.999 kW
-
-
199.99 kW
-
-
1999.9 kW
-
-
-
-
-
-
-
-
-
-
-
-
DC input Option
-
-
Option
• Instruction manual
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
96
■ Bracket
54
DI
Cautions during Wiring
19999
• Unit: mm, Use terminals of size speci昀椀ed below.
-
-
-
≥3.5
≤7.0
-
-
Connections
-
INPUT
-
-
1
2
3
-
+
-
Option
HIGH
LOW
• Power option
8
6
7
24 - 70 VDCᜡ
12
■ Panel cut-out
20
8
4
5
6
7
SOURCE
100 - 240 VACᜠ 50 / 60 Hz
100
≥ 116
92
+ 0.8
0