If select F or N mode , when counting value reaches the preset value , output will maintain , therefore there is no
menu in function setting mode.
output is
If
S,T, D mode , input mode can only choose Ud-A,B, C mode .If input mode choose Up/Down mode , output mode can select
any mode except S , T , D
When select D output mode , if counting frequecy more than 1Kcps , as there is a responding time of the relay , it may cause the output
action abnormal , so please choose SSR output .
When max. counting speed is 5kcps or 10kcps , if change the output mode to
In function setting mode , external input signal still can be recognized , when exit the function setting mode , display value and output
will reset automatically .
8 .Timing function mode setting
Setting Mode
MD
MD
MD
MD
MD
MD
MD
MD
Selection and Setting
U
Up
Down
.
select output delay time
use
and
to select input mode .
Page 06
mode , counting speed turn to 1k cps automatically .
"D"
"OUT2 output time"