GENERAL

The OptiNID 500 Optical Demarcation Closure (OPN-500) is designed for installation in either indoor or outdoor
environments. The closure is equipped with an integrated splice tray which will hold up to six single fusion splices.
The closure will house one LGX
be either wall or pole mounted and the small form factor makes it ideal for FTTx demarcation applications.

SPECIFICATIONS

Parameter
Dielectric Strength
High Temperature Storage/Mold Stress °F (°C)
Temperature Cycling with Humidity °F (°C)
Impact Test °F (°C)
Drop Test °F (°C)
Rain
UV Resistance (Days Exposed)
Salt Fog (Days Exposed)
Flammability
Chemical Resistance
30 Days at 100°F and 95% RH
Material
Dimensions (H x W x D) in. (cm)
Cable Entrance in. (cm) diameter - Input
Covers

PACKAGE CONTENTS

A. OPN-500 Optical Demarcation Closure
B. Adapter Plate (Optional)
118 adapter plate allowing for up to six bulkhead connections. The OPN-500 may
®
INSTALLATION INSTRUCTIONS
OptiNID
Value
Minimum 2500Vrms for 1 minute
14 Days at 159 (70.55)
150 Days Cycling from 40 - 140 (4.44 - 60) with 95% RH
-40 (-40), 5ft/lbs on all external surfaces
-40 (-40), 5ft onto concrete surface four times
24 hours at 10 psi
60 per ASTM-G26-84
60 per ASTM-BLL-90
UL95-5V
Resists chipping and/or cracking when subjected to house
paint, wasp spray, sulfuric acid, kerosene and sodium hydroxide
UL
Listed Flame Retardant Thermoplastic Alloy
®
6.3 x 7.8 x 2.0 (15.7 x 19.7 x 5.0)
1 x 3/4" NPT (1.130"); 2 x 1/2" NPT (0.875")
Standard, molded-in snap finger and "F" termination