Adexa HSQ-962B Manuel d'instruction - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Adexa HSQ-962B. Adexa HSQ-962B 6 pages. Electric cooker with electric oven
Instruction Manual
the product must wait until the cooker is completely cooled.
Ⅴ、Installation Notes:
1、The operating voltage of the equipment must be in accordance with the supply voltage.
2、Users need to install appropriate leakage protection switches near the furnace body.
3、Copper equipotential terminal is arranged below the rear part of the box body. Copper
core conductor of no less than 1.5mm2 is used to connect reliably according to the
regulations.
4、The installation of this stove should be operated by professional and technical personnel.
5、Before use, check whether the wiring is loose, whether the voltage is normal and whether
the safe grounding is reliable.。
6、The shell of the machine must be grounded to ensure safety.。
This product needs to be operated by a trained chef or experienced person.
No modification! The modification of products will lead to serious accidents.
Cut off the power supply before cleaning。
When cleaning, do not flush the original stoves or appliances with water. Electric
shock accidents may occur because of water leakage.
High temperature can cause burns. Because of the high temperature, do not touch the
panel directly by hand, especially near the high temperature area in the center of the
heating plate.
It is forbidden to use power sources other than the voltage indicated by the product.
It is forbidden to use switches that do not conform to safety regulations.
When lightning approaches, the power supply should be disconnected to stop using.
Avoid electrical damage caused by lightning strike.
It is forbidden to use hard and sharp objects to destroy the surface of furnace body and
electric heating disc.
Installation and maintenance of electrical appliances must be carried out by qualified
professionals.
Hands should be dry in installation and use, plugs and switches should be kept dry.
If the soft wire of power supply is damaged, in order to avoid danger, it must be
replaced by full-time personnel such as the manufacturer or its maintenance
department.
Ⅵ、General Fault Handling:
Fault phenomenon
1、 Close the switch and turn on
the power supply. The
power indicator is not on or
heated.
2、The heating indicator is on,
but the temperature does not
rise.
3、The heating indicator is on
and thesetting temperature
is not raised.
4 、 Temperature control is
normal, but indicator is not
on
Special attention
Reason
1、There is no power
supply on the line.
1、Loosening or falling
off of heating pipe
wiring
2、The heating pipe has
burnt out.
1、The thermostat has
burnt out
1 、 Indicator
lamp
burned out
Elimination method
1、Check power supply
1、Fastening the connecting
wires and screws at both
ends of the heating pipe
2、Replacement of heat pipe
、
1
Replacement
Temperature Controller
1、Replacement of indicator
lamp
of
4