Bristan PRISM BLK SHWR PK Instructions d'installation et manuel de l'utilisateur
Parcourez en ligne ou téléchargez le pdf Instructions d'installation et manuel de l'utilisateur pour {nom_de_la_catégorie} Bristan PRISM BLK SHWR PK. Bristan PRISM BLK SHWR PK 2 pages.
Specifications
Cold Water Supply
Dynamic Water Pressure
Min: 0.2 bar
Max: 5.0 bar
3.0
3.0
2.0
2.0
4.0
4.0
1.0
1.0
0.
5.0
0.
5.0
Min: 5°C Max: 25°C
Pressure
Pressure
BAR
BAR
IMPORTANT
Maximum Static Pressure: 10.0 bar
Tools You'll Need
Flat head
Socket Spanner
Drill
Adjustable Spanner
Screwdriver
Prior to Installation
All products manufactured and supplied by Bristan are safe to use
provided that they are installed, operated and receive regular
maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999
and current by-laws. For full Installation Requirements & Notes (IRN)
please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease
of future maintenance. Before installing this product the water supply
must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/
servicing purposes.
Before drilling into walls, check that there are no hidden electrical
wires, cables or water supply pipes. This can be checked with the
aid of an electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
This product must not be modified in any way
as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water
Authority or the Secretary of the Institute of Plumbing,
address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product Code: PM2 SHCDIV BLK (D1)
Inlet Water Temperature
Inlet Dimensions
Hot Water Supply
65°C
25°C
5°C
65°C Recommended
The inlet hot water must
be at least 10°C above the
required blend temperature.
Pipe Cutter
Silicon Sealant
Hexagonal Keys
Cavity Dimensions (mm)
Minimum
Fitting Depth: 50mm
Maximum
Fitting Depth: 75mm
Concealing Plate
Adjustment Range: 25mm
Pack Contents
x1
x1
x2
x1
x2
Valve Configuration
1
Yellow Flow
Limiter (Hot)
Installation
150mm
1
Centres
Install suitable
Inlet Connections
batons (if required)
into the cavity. Take the
15mm
finished wall surface into
Compression
consideration when fitting
the valve into the cavity.
Mark the position of
the valve; drill and
plug holes to suit.
3
Pipe & Wire Detector
Hot
Connect the inlet
pipes ensuring the
olives are fitted.
25
50
6
x2
2
Increase
Temperature
x2
x2
Temperature
Green Flow
Limiter (Cold)
Remove the inlet elbows and filters.
Remove the plastic inserts from the valve
inlets and insert the flow regulators.
Replace the elbows, ensuring the
filters are fitted.
2
Cavity Space
75mm
50mm
Baton
Secure the valve using the screws supplied
(solid walls only) or a suitable alternative.
4
Cold
Plumb your chosen
outlets into the valve.
Turn on the water
supply and check the
valve for any leaks.
Temperature Adjustment
1
Fit the
handles.
2.5
mm
3
Turn the spindle
to increase or
decrease the
temperature.
Check the
temperature and
Fit the temperature
adjust until you
handle back in the
Decrease
achieve the
maximum hot position.
desired result.
2
Screw the shrouds
onto the valve.
5
Draw around
the concealing
plate as a template,
measuring in by
10mm to give
clearance. Finish the
wall surface. Using a
silicon sealant, push
on the concealing
plate and hold
firmly until set.
Turn the
handle to the
maximum
temperature
setting, then
remove it.
2.5
mm
2.5
mm