General Cleaning
Bristan products are made from premium materials,
with hand polished, PVD, EPD or electroplated finishes.
Your shower should be regularly cleaned with warm water,
a mild pH-neutral liquid soap, and polished with a soft
cloth. Any residues from soap, toothpaste, shampoos and
shower gels can cause blemishes if not rinsed off straight
after use.
Household bleaches and cleaners contain harsh chemicals
and may damage the surface finish. Avoid using abrasive
cloths, scouring pads, scrub sponges, steel wool or
anything similar.
Maintenance - Cartridge Cleaning
2
1
Remove the
handles.
IMPORTANT
Isolate the
water supply
before
starting!
Gently
remove the
concealing
plate from
2.5
the wall.
mm
4
5
Remove any O-rings and soak all
components in de-scaler and wash off
in clean water. Examine all seals and
replace if needed. Use WRAS
approved silicon based grease
on all seals.
Notes
Operation
Off
Left
Outlet On/
Increased
Flow
Increased
Temperature
3
Unscrew the
shrouds.
Remove the
cartridges
and piston.
6
1
2
Increase
3
Temperature
Reverse the
installation steps,
ensuring the
Temperature
temperature stop
is aligned correctly.
Troubleshooting
Symptom
Right
Instantaneous water heater cycles on and off
Outlet On/
Increased
Flow
Are the water supply pressures balanced?
No flow or
low flow rate
Hot or cold water being drawn off elsewhere
Decreased
causing pressure changes or instantaneous
Temperature
Airlock or partial blockage in the supply
Maximum
Water
Temperature
too Hot/Cold
Hot water temperature is less than 10°C
Outlet Water
above the required blend temperature
Temperature
too Hot/Cold
Instantaneous water not igniting because the
23
mm
Instantaneous water not igniting because the
Follow the
Temperature
Adjustment steps
if required.
Only hot/
cold water
from Shower
Valve
This is normal for a short time after using the
Water
dripping
from shower
Decrease
Shower does
not turn on
Our Guarantee
At Bristan, we want to make things as easy as possible for our customers. That's why we offer
solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273
where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
Bristan Group Ltd.
UK:
Bristan Group, B78 1SG.
EU:
Masco Europe S.à.r.l., 14 Rue Strachen
6933 Mensdorf, Luxembourg.
Cause
Partially closed isolation valve.
as flow rate or pressure is too low.
Head of water is below the
minimum distance required.
If pressures are unbalanced, a pressure reducing valve
Do not use other water outlets when using the shower.
boiler temperature changes.
Flush through pipework and filters to ensure removal
pipework.
Check the hot and cold feeds. The shower will not
Hot/Cold water supply has failed
Maximum Water Temperature
Refer to the Temperature Setting section to set your
needs adjusting.
Filter/pipe blockage
Installtion conditions outside
operating parameters.
Adjust hot water temperature or wait for water to
Increase water flow rate through the system. Refer to the
Maintenance section to clean/check the cartridge and filters
water flow rate is too low.
for any damage. Contact your boiler manufacturer.
Refer to the specification for system requirements.
water pressure is too low.
Check the water inlet connections are the correct way
Inlet water supplies are reversed.
around: Hot on the left, Cold on the right when viewed from
Flush through pipework and filters to ensure removal of
Filter/pipe blockage
This is caused by residual water tension, the build up of
shower.
If water continues to drip,
Remove cartridge and clean, refer to 'Maintenance' section
possibly due to the cartridge
Closed isolation valve.
Mains water supply turned off.
Customer Service: +44330 026 6273
Web:
www.bristan.com
Email:
A Masco Company
Remedy
Open isolation valve.
Increase water flow rate or
pressure through system.
Refer to the specification for the
minimum distance required.
should be used for optimum performance.
of debris and any airlocks.
work if either fails.
desired maximum temperature.
Flush through pipework and filters to ensure
removal of debris and any airlocks.
Refer to the specification for the
minimum distance required.
reheat if a stored water system is used.
Increase water pressure through the system.
Contact your boiler manufacturer.
the front. Rework pipework as necessary.
debris and any airlocks.
water in the shower.
before starting any maintenance.
Open isolation valve.
Turn on mains water supply.