• When installing the appliance in a configuration where washers and dryers are stacked vertically, there are several
methods that have proven successful
Clearance
Considerations
-
Option I - 3 inch clearance all around the machine Which allows for adequate air flow for the dryer
Option 2 - If zero clearance on the sides then installer must allow for a minimum of t inch at the rear of the unit
and a minimum of 1 inch clear space on the top of the dryer to allow for air movement to the back of the dryer
in
addition, in an enciosed installation installer must provide a air intake area of no less than t2 sq in of un_obstructed
free air space through the door, around the units to the back of the dryer to allow for adequate air intake
Otherwise
installer must apply a label that instructs the user that the dryer cannot be operated with the door closed
Duct hose length:
A maximum of 12 inches of 4 inch flex hose can be used to vent the dryer
Electrical Hookups: Each machine must have it's own 15 amp circuit in order to run the Washer and Dryer
simultaneously
Stacking
Installation:
Option t - Although we recommend the use of the Majestic Stacking
Brackets (Model 17-I057) alternative mounting bracketry may be used if bracket configuration
is approved by Majestic Appliances
instructions are included with the mounting brackets
as to their application
Majestic brackets ensure that no wiring or hoses are impacted by the
installation
Option 2 _Mount the dryer on its own shelf, utilizing the same guidelines as if it were mounted
on a floor (See page 6)
tf you have any other unique needs do not hesitate to call us on our toll-free number and we wi!t
assist you
CORRECT
LEVELING
OF UNIT IS ESSENTIAL
It is important for the machine to be perfectly level The angle of
inclination on the work surface must not be more than 2 degrees
For this reason the machine is fitted with adjustable feet used for
leveling the machine before use In the case of carpeted flooring,
remember to check that the ventilation in the support area is not
plugged
Exhaust
Duct Installation
• Check that all ducting is lint free, clean with duct tape to secure atl joints A maximum
of 12 inches of 4 inch flex hose can be used to vent the dryer
• The exhaust duct must end with an approved exhaust vent hood with swing out
dampers or appropriate louvers
• Flex or rigid metallic ducting is recommended
. Exhaust duct should be short and straight and slope downwards and away from
the appliance
Long exhaust duct runs can increase drying time, collect tint and may
increase drying times
IMPORTANT!
THE EXHAUST DUCT SHOULD NOT BE
INSERTED
INTO A CHIMNEY, WALL , CEILING OR CONCEALED
SPACE OF
STRUCTURE