4.4. FREQUENCY AND % DUTY CYCLE MEASUREMENTS

WARNING: Observe all safety precautions when working on live
circuits.
1. Set the rotary function switch to the Hz %
position.
2. To select Frequency or % Duty Cycle,
press the MODE button until the "Hz" or
"%" symbol appears on the LCD display.
3. Insert the black test lead into the COM
input jack and the red test lead into the V
input jack.
4. Touch the test lead probes to the circuit
under test.
5. Read the frequency or % duty cycle on
the LCD display.

4.5. RESISTANCE MEASUREMENTS

WARNING: Never test resistance on a live circuit.
1. Set the rotary function switch to the
position.
2. Press the MODE button until the "Ω" symbol
appears on the LCD display.
3. Insert the black test lead into the COM input
jack and the red test lead into the Ω input jack.
4. Touch the test lead probes to the component
under test. If the component is installed in a
circuit, it is best to disconnect one side before
testing to eliminate interference with other
devices.
5. Read the resistance in on the LCD display.
13