Major tech MT26 Manuel d'instruction - Page 15

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Major tech MT26. Major tech MT26 20 pages. 600v ac/dc bluetooth multimeter

Major tech MT26 Manuel d'instruction

4.8. CAPACITANCE MEASUREMENTS

WARNING: Safely discharge capacitors before taking capacitance
measurements.
1. Set the rotary function switch to the
position.
2. lnsert the black test lead into the COM input
jack and the red test lead into the Ω input jack.
3. Press the MODE button until the "nF" symbol
appears on the LCD display.
4. Touch the test lead probes to the capacitor
under test.
5. Read the capacitance value on the LCD display.
It may take up to a minute to get a stable
reading on large capacitors.

4.9. TEMPERATURE MEASUREMENTS

WARNING: Do not touch the temperature probe to live circuits.
1. Set the rotary function switch to the °C °F
position.
2. Press the MODE button to select readings in °C
or °F.
3. Connect the Temperature Probe to the Banana
Plug Adapter. Note the - and + markings on the
adapter. Connect the adapter to the meter,
making sure the - side goes into the COM input
jack and the + side goes into the °F °C input
jack.
4. Touch the tip of the Temperature Probe to the
object being measured. Keep the probe touching
the object until the reading stabilizes (about 30
sec).
5. Read the temperature on the LCD display.
15