Century CJW2500X SERIES Manuel du propriétaire - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Century CJW2500X SERIES. Century CJW2500X SERIES 20 pages. Epa approved high efficiency air tight insert

CHIMNEY
CONTACT YOUR LOCAL BUILDING AUTHORITY FOR APPROVED METHODS OF
INSTALLATION
a) A chimney connector shall not pass through an attic, roof space, closet, floor, ceiling or
simular concealed space. Where passage through a wall or partition of combustible
construction is desired, the installation shall conform to CAN/CSA-B365 (in Canada). In the
USA, check with local building officials for requirements in your area.
b) It is advisable to have your masonry chimney inspected for deterioration such as cracks
and crumbling mortar before you install your unit.
c) To help ensure a good draft, the top of the chimney should be at least 3 feet (914mm)
above the point of penetration through the roof, and be at least 2 (610mm) feet higher than
any point of the roof within 10 feet (3048mm).
d) Do not use makeshift compromises during installation.
e ) Do not remove bricks or mortar from the fireplace.
CANADA: This fireplace insert must be installed with a continuous chimney liner of
6"(152mm) minimum diameter extending from the flue collar to the top of the chimney. The
chimney liner must conform to the class 3 requirements of CAN/ULC-S635 STANDARD for
lining systems for existing masonry or factory-built chimneys and vents, or CAN/ULC-S640
STANDARD for lining systems for new masonry chimneys.
USA: This fireplace insert must be connected to:
1) A chimney complying with the requirements for type HT chimneys in the Standard for
Chimneys, Factory-built, Residential Type and building Heating Appliance, Ul103, or
2) A code-approved masonry chimney with flue liner.
3) See page 8 for alternate chimney installation.
6" (152mm) min dia Stainless steel Flexible liner
NOTES:
A stainless steel adapter is
recommended for fastening the
stainless steel flexible liner to the flue
collar.
Male or crimped end of the adapter
must be installed inside the flue collar.
Drill flue collar to permanently fasten
stainless steel adapter using a
minimum of 3 screws.
Fasten stainless steel chimney liner to
the stainless steel adapter using
manufactures instructions.
7