GAPOSA XQ50 Manuel - Page 14

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} GAPOSA XQ50. GAPOSA XQ50 15 pages. Tubular motors with mechanical limit switch and integrated receiver.
Également pour GAPOSA XQ50 : Manuel d'instructions (8 pages), Instructions (4 pages), Manuel de programmation rapide (7 pages), Manuel d'instructions (13 pages), Manuel (13 pages), Manuel (16 pages), Manuel d'instructions (8 pages)

GAPOSA XQ50 Manuel
DEACTIVATING OBSTACLE
SENSITIVITY
Press for 1 second and release
1
PROG-FC button.
2
Press UP button
As soon as the motor runs upward press
3
DOWN button.
As soon as the motor runs downward
4
press UP button.
As soon as the motor runs upward press
5
DOWN button.
As soon as the motor runs downward
6
press UP button.
When the motor runs upward press and
7
hold DOWN button until you get a jog as
confirmation of deactivation.
ACTIVATING OBSTACLE SENSITIVITY
Perform the same sequence. At step 7. you get 2 jogs as confirmation of
activation.
1"