GAPOSA XQ50 Manual
DEACTIVATING OBSTACLE
SENSITIVITY
Press for 1 second and release
1
PROG-FC button.
2
Press UP button
As soon as the motor runs upward press
3
DOWN button.
As soon as the motor runs downward
4
press UP button.
As soon as the motor runs upward press
5
DOWN button.
As soon as the motor runs downward
6
press UP button.
When the motor runs upward press and
7
hold DOWN button until you get a jog as
confirmation of deactivation.
ACTIVATING OBSTACLE SENSITIVITY
Perform the same sequence. At step 7. you get 2 jogs as confirmation of
activation.