CORNING Eclipse 02U Manuel de démarrage rapide - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} CORNING Eclipse 02U. CORNING Eclipse 02U 5 pages. Coupler shelf
Page 4
9.
Identification Label
9.1
A label is provided to identify transmitter inputs
(Tx), node outputs, power levels (insertion loss), and
miscellaneous descriptions associated with each I/O
port (Figure 6).
9.2
To access the label card, pull up at the tab in the
center of the shelf. The card may be pulled completely
out of the unit to write information on the label
(Figure 6).
9.3
The "Loss (dB)" information is always included
and represents the measured insertion loss of each
port. All other information can be added as required.
SRP-009-222
10. Connector Care
Connectors are extremely delicate devices. Therefore
the following precautions should always be observed.
• At installation, use a clean tissue soaked in isopropyl
alcohol to gently clean the connectors at the end
of the jumper or pigtail. Clean all the areas of the
connector that will contact the connector sleeve.
• Do not press on connectors as you clean. Doing so
may scratch or crack the connector surface, making
it unusable.
• Carefully press the connector into its receptacle and
tighten. Do not overtighten. Doing so can damage
the connector surface.
• Do not allow the connector body (ferrule) to turn
as you screw it into place. Doing so will allow
the surfaces to grind against each other causing
scratches on the connector surface.
• The connector should fit into its receptacle easily. If
it binds, back it up. Do not force.
• Clean external components of installed connectors
at regular intervals as recommended by their
manufacturer.
Issue 3
KPA-2553
Figure 6