4.
INSTALL ALL MODULES
Note:
For modules with ejectors (i.e., OIM, OIX, and ACM)
– verify that the ejectors are completely open when
inserting in dedicated slot and then push in until
the module clicks in to the backplane. Figure 4
shows example of module type captive screws and
ejectors.
Step 1:
Refer to Figure 5 for module locations. Remove
blank panel and slide in the relevant module
(chassis slots are 100 percent mistake proof):
• (One) ACM
• (One to two) PSM – for single-power supply
• (One to two) OIX – for single OIX installations,
• (One to 12) OIM — no need to terminate
Step 2:
Secure modules into the OIU backplane by:
• Closing ejectors firmly (for relevant modules)
• Tightening the captive screws
5.
GROUND CHASSIS
The grounding connection is performed via a two-hole, standard
barrel grounding lug located on the chassis rear panel (see Figure 6).
Prise de terre du châssis OIU:
La mise à la terre est réalisée en utilisant une cosse deux trous a
œillet standard, située à l'arriè du chassis OIU (voir Figure 6).
Corning Optical Communications
installations, install the PSM in either (PSM) slot.
the second OIX slot must be occupied with an
expander termination module (ETM).
unoccupied OIM slot.
Figure 4.Module Ejectors
Figure 5. Location of OIU Chassis Modules
Figure 6. Location of Chassis Grounding Lug
Quick Installation Sheet | CMA-263-AEN | Page 4