PRIMERGY BX620 S2 / BX620 S3
PRIMERGY BX620 S3
Configuration Diagram
Memory
CPU
DIMM Slot 8
Xeon®
DIMM Slot 4
5080 (3.73GHz)/
DIMM Slot 7
5060 (3.20GHz)/
DIMM Slot 3
5050 (3GHz)
DIMM Slot 6
DIMM Slot 2
Xeon®
DIMM Slot 5
5080 (3.73GHz)/
DIMM Slot 1
5060 (3.20GHz)/
5050 (3GHz)
Expansion Board Slot *1,*2
*1. When 2Gbit/s FC I/O Module (PG-FCD102) is mounted on Expansion Board Slot of BX620 S2, FC Switch Blade (PG-FCS102) or FC Pass-Thru Blade (PG-FCB101)
is required to be mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*2. When 1Gbit/s Ethernet I/O Module (PG-LND101) is mounted on Expansion Board Slot of BX620 S2, Switch Blade (PG-SW104/PG-SW105) or GbE Pass-Thru Blade (PG-LNB101)
is required to be mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*Components installed as standard configuration marked in grey.
Mountable I/O Options
BX620 S3 ( In case that Expansion Card Slot Module (PGBCS104) is applied. )
Mountable Cards
Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp
BX620 S3 ( In case that Expansion Card Slot Module (PGBCS103) is applied. )
Mountable Cards
SCSI Ctrl U160 lp
*. PCI card (Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L/PGB2861L)) should be mounted on Expansion Card Slot Module (PGBCS104).
PCI card (SCSI Ctrl U160 lp (PG-1301L/PGB1301L)) should be mounted on Expansion Card Slot Module (PGBCS103).
The slot of mounted PCI card is at front side of BX600 S2 Blade Server System Unit (PGUR3SC1).
The cable connected to PCI card can be gone from front side to back side of BX600 S2 Blade Server System Unit (PGUR3SC1)
by using Front-Rear Cable-Thru kit (PG-R1CM1).
Front-Rear Cable-Thru kit (PG-R1CM1) is mounted just under BX620 S3 and occupies 1U.
Notes on addition of BX620 S3
In case that BX620 S3 are added on BX600 S2 Blade Server System Unit (PGUR3SC1), it may be necessary
to change firmware version of Management Blade of BX600 S2 Blade Server System Unit (PGUR3SC1).
For details, please refer to accompanying material of BX620 S3.
2.5 inch HDD Bay 1
(hot plug)
2.5 inch HDD Bay 2
(hot plug)
Expansion Card
Slot Module
Max No.
Bus
of Mount
PG-2861L /
PCI Express (x4)
PGB2861L
Max No.
Bus
of Mount
PG-1301L /
PCI/64bit
PGB1301L
Hard Disk 2.5inch Bay (hot plug)
Standard Drive Cage (HDD x 2ports)
Bay 1
SAS
Bay 2
SAS
Remarks
1
LowProfile PCI Express Card
Remarks
LowProfile PCI Card,
1
For PRIMERGY SX10