How to Replace the PF Kit (1850/1870N)
Step 2
1. Apply enough pressure to un-clip the separation
pad by lifting it upwards and slightly back as
shown by the arrow in Figure 14.
Please note: There is a spring under the separation
pad assembly. Make sure you do not lose the spring.
Step 3
1. Release the separator pad but leave the spring
in the tray as shown by the arrows in Figure 15.
Step 4
1. Install the new separation pad by lining up the
spring with the small tabs on the bottom of the
separation pad and clipping it into place by push-
ing down to secure it as shown by the arrows in
Figures 16 and 17.
2. To check if the separator pad is installed
correctly, press it down and release. It should
return to its original position. If not repeat
from Step 2.
Step 5
1. Re-install the drum, toner, and paper tray into
the machine. Plug in the power cord and turn
on the printer.
2. Wait for the printer to warm up with a Ready
Message on the Control Panel Display.
3. The PF Kit life counter needs to be reset to
clear the "Replace PF Kit" maintenance
message. To do this, press the GO and + buttons
at the same time. The message "Reset Parts
Life" will flash on the screen for one second,
then the display will change to "PF Kit 1".
Once this message is displayed, press the SET
button once. The counter will now be reset.
Please note: If "Pause" is displayed after attempt-
ing to reset the counter, please retry pressing GO
and + buttons at the same time. The message
"Reset Parts Life" will flash on the screen for one
second, then the display will change to "PF Kit 1".
Once this message is displayed, press the SET
button once. The counter will now be reset.
4. Print a test page by depressing the set button
three times.