Fujitsu ETERNUS DX Disk Manuel de configuration - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel de configuration pour {nom_de_la_catégorie} Fujitsu ETERNUS DX Disk. Fujitsu ETERNUS DX Disk 21 pages. Server connection, fcoe for linux driver settings for converged network adapter cards
Également pour Fujitsu ETERNUS DX Disk : Manuel de l'utilisateur (35 pages), Manuel de l'utilisateur (42 pages), Manuel de configuration (28 pages), Manuel de configuration (44 pages), Manuel de configuration (28 pages), Manuel de configuration (29 pages), Manuel de configuration (25 pages), Manuel de configuration (32 pages), Manuel de configuration (35 pages), Manuel de configuration (31 pages), Manuel de configuration (43 pages), Manuel de configuration (24 pages)

Fujitsu ETERNUS DX Disk Manuel de configuration
Chapter 1
Setup Procedure for Emulex Converged Network Adapter Cards
1.2
Setting Up the Converged Network Adapter Cards
2
Turn on the server, and press the [Alt] + [E] keys or [Ctrl] + [E] keys while the following message is
displayed.
!!! Emulex OneConnect FCoE BIOS !!!, Version 4.01a0
Copyright (c) 1997-2010 Emulex. All rights reserved.
Press <Alt E> or <Ctrl E> to enter Emulex BIOS configuration
utility. Press <s> to skip Emulex BIOS
Emulex OneConnect FCoE BIOS Utility starts.
3
Select the Converged Network Adapter card from which information is to be obtained with the [h] and
[i] keys. Press the [Enter] key.
4
Check the [Mem Base] and [Port Name] values.
The value of [Mem Base] is the physical address and the value of [Port Name] is the Converged Net-
work Adapter card WWN.
01:
OCe10102-FM
Mem Base:
Port Name:
Vlan ID:
5
Record the physical address and WWN in the "WWN instance management table for the server".
Refer to
The following shows an example of this.
WWN instance management table for the server
Host name
IP Address
Physical slot
name
slot0
Details of contents
The details of contents for the WWN instance management table for the server are as follows:
Host name:
Record the host name.
IP Address:
Record the IP address of the server.
Physical slot name:
Record the slot position of installed Converged Network Adapter card.
For the installation location, refer to the User's Guide for each server.
Converged Network Adapter card WWN:
Record the [Port Name] value. This value can be confirmed in
Emulex OneConnect FCoE BIOS Utility, XB4.01a0
Physical address
F94C0000
Firmware Version:
10000000C99CDD9B
1002
DCBX mode:
CEE mode
"Appendix A WWN Instance Management Table for the Server (Blank)" (page
Converged Network Adapter
card WWN
10 00 00 00 C9 9C DD 9B
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for Linux
Copyright 2018 FUJITSU LIMITED
Bus#: 09 Dev#: 00 Func#: 02
2.702.200.17
BIOS: Disabled!
Node Name:
20000000C99CDD9B
Converged Network Adapter card WWN
Instance name
Physical address
F94C0000
Step
7
19).
Cable tag
4.
P3AM-6402-11ENZ0