Aqua HC 100 Manuel d'utilisation et d'entretien - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Aqua HC 100. Aqua HC 100 20 pages.
Également pour Aqua HC 100 : Manuel d'utilisation et d'entretien (19 pages)
- 1. Table of Contents
- 1. 1 General Comments
- 2. 2 Technical Characteristics
- 2. Hydraulic Connection
- 2. Programming
- 2. MAINTENANCE 3.1 General Maintenance Comments
- 3. 3 0 Maintenance
- 3. Replacing Worn Parts
- 3. Commonly Reported Problems
- 3. Chemical Compatibility Table
- 3. Warranty Certificate
- 3. Connections
2.0 TECHNICAL CHARACTERISTICS
2.1 General rules
Install the pump:
In a Vertical reinforcement (ex: Wall) or on the pump stand (optional) so that
Far from a hot source in dry places at maximum temperature of 45°C and
In a ventilated place and easily accessible by an operator for periodical
At a suitable height above the chemical up to a maximum height of 1.5 meters.
Do not install the pump over the tank in presence of liquids that emanate fumes
2.2 Standard accessories supplied
1 Foot valve / Strainer.
1 Injection fitting
2 meters opaque PE delivery tubing.
2 meters PVC clear suction tubing.
2 meters PVC clear priming tubing
2.3 Electrical characteristics
Power supply: 230 VAC 50/60 HZ
Upon request (all series)
115 Volt AC 50-60 Hz
Only for series HC1
24/12 Volt DC – 24 Volt AC
2.4 Electric connection CAUTION !!!!!
Verify that the earth system is perfectly functional and complies with the applicable
regulations. Ensure the unit is connected to a circuit protected by a highly sensitive (0.03A)
RCCB circuit breaker. If unsure please consult a competent electrician. Verify that the rated
values of the pump are compatible with those of the mains. Never install the pump directly in
parallel with inductive loads (e.g. motors/solenoid valves) if necessary, use an isolating relay.
There are 2 protection devices inside the pump: a varistor and a fuse.
HC100/N/240717/NW
the pump head stays always in vertical position +/-15°.
minimum 0°C.
maintenance.
If for xigency of the plant it's necessary to install the pump under the level of
the chemical, you need to use an injection valve or an anti siphon valve.
unless it is hermetically closed.
I- Switcher or multi-pole security device
E- Motor or generally inductive charge
3
ENGLISH
P- Metering Pump
R- Relay
A- Supply voltage