9.0 Maintenance and Servicing
Designed to be maintenance free the Obstruction Lights requires minimal attention, though the following maintenance
and servicing information is provided to help ensure the life of your Avlite product.
•
Occasional cleaning of the dome lens may be required using a cloth and warm soapy water.
External 36V Battery System (SLA)
Red Status LED Name
Slow
High
Off
Optimal Between 37.5V – 40.5V
1 Quick
Good
2 Quick
Ok
3 Quick
Low
4 Quick
Flat
External 48V Battery System (SLA)
Red Status LED Name
Slow
High
Off
Optimal Between 50.0V – 54.0V
1 Quick
Good
2 Quick
Ok
3 Quick
Low
4 Quick
Flat
Voltage
40.5V and above
Between 36.0V - 37.5V
Between 35.0V – 36.0V
Between 32.0V - 35.0V
32.0V and below
Voltage
54.0V and above
Between 48.0V - 50.0V
Between 47.0V – 48.0V
Between 43.0V - 47.0V
43.0V and below
Description
Voltage is higher than expected, this may indicate a problem
with the solar regulator.
Voltage is correct for a charged battery
Voltage is correct, this is where the lantern returns to normal
operation
Voltage is a little low, but within expectations.
Voltage is low, this is where the alarm relay is first activated
Voltage is flat, this is where the main LEDs are turned off and
the flat battery cutoff is enabled
Description
Voltage is higher than expected, this may indicate a problem
with the solar regulator.
Voltage is correct for a charged battery
Voltage is correct, this is where the lantern returns to normal
operation
Voltage is a little low, but within expectations.
Voltage is low, this is where the alarm relay is first activated
Voltage is flat, this is where the main LEDs are turned off and
the flat battery cutoff is enabled